Two phase separator
The primary function of Two phase separator extracts liquids from natural gas. They are available in vertical, horizontal, and spherical configurations. Two-phase separators are extensively used in onshore or offshore oil and gas facilities and petrochemical applications.Two-phase separators are widely used for liquid-liquid or solid-liquid separation at processing facilities.
Two-stage separators have the same basic operating principle as three-phase systems but can only separate oil and gas mixtures. Like a three-phase system, it can be oriented as a horizontal two-phase separator or vertical two-phase separator. Due to their compact nature, vertical two-phase separators can only accommodate smaller volumes of fluid that require shorter residence times.
Specifications
Product Name | Two Phase Separator |
Brand | Bossmanfilter |
Gas flowrate: | 10-75 MMSCFD |
Separator Vessel Length (S/S): | 6-18 ft |
Vessel diameter: | 24" to 48" diameter-other custom sizes available |
Standard Design Pressures: | 1440 psig on 42" vessel, 2000 psig on 30" vessel |
Maximum Design Temperature: | 200℉ (93℃) on 30", 125℉ (52℃) on 42" |
Minimum Design Temperature: | -20℉ (-29℃) on 30", -10º F (-23℃) on 42" |
Material of Construction: | ◼ Shell - SA-516-70 ◼Elliptical Heads - SA-516-70◼Nozzles - SA-105, SA-350-LF2 ◼Drag Skid - A572 GR-50, A500 GR-B,◼Structural components - SA516-70, A36 |
Applicable Standards: | ◼ASME Section VIII, Division 1◼NACE MR0175◼ANSI B31.3 Class M (H2S)◼API 12J◼Class I Division I (UL, Exp)◼Lethal Service (H2S)◼Certificates of Conformance |
Non-destructive Test (NDT): | ◼Radiography ◼Magnetic Particle Examination ◼ Liquid Penetrant Examination ◼ Ultrasonic Examination◼ Brinell Hardness◼ Charpy Impact |
Mechanical Specifications: | ||||||
External Connections: | Inlet | Gas Outlet | Oil Outlet | Water Outlet | Trash | |
30" | 3" | 3" | 2" | 2" | 2" | |
42" | 3" | 3" | 2" | 2" | 2" |
Level and Flow Monitoring: | ||
30" | 42" | |
Meter Run(s) | 4" | 6" and 4" |
Sight Glasses | Oil and Water | Oil and Water |
Vessel misc.(unless otherwise specified, all vessel connections are ANSI 900 raised face flanges) | ||
30" | 42" | |
Clean outs | 1 - 4" | 2 - 6" |
Inspection | 1 - 6" | 1 - 8" |
Washout-Inlet Head | 1 - 6" | 1 - 6" |
Washout-Outlet Head: | 1-6" | : |
Manway: | None | 1-18" |
Pressure Safety Valve(PSV): | 2-3" | 2-3" |
Liquid Level Controls | 2-2"(External) | 2-2" (External) |
Coating Options: | Sandblast: commercial, near white and white metal SSPC-SP Codes Available, Paint: 2 & 3 coat corrosion resistant | |
Application | ◼ Gas pipelines◼Gas field treatments◼Metering & regulating stations◼Petrochemical plants◼Gas processing plants◼Chemical processing plants | |
Working Media | ◼Natural gas◼Methyl Chloride ◼Methane ◼Hydrogen ◼Propane ◼Propylene◼Helium ◼Halocarbons◼Ethylene ◼Ethane ◼Carbon Monoxide◼Carbon Dioxide ◼Ammonia ◼Biogas ◼Air |
Application | |||
Gas pipelines | Gas field treatments | Petrochemical plants | |
Gas processing plants | Metering & regulating stations | Chemical processing plants | |
Working Media | |||
Natural gas | Methyl Chloride | Methane | Hydrogen |
Propane | Propylene | Helium | Halocarbons |
Ethylene | Ethane | Carbon Monoxide | Carbon Dioxide |
Ammonia | Biogas | Air |